-40%

Siemens PFA 100 Platelet Function Analyzer DADE Behring Hematology LAB B4170-00

$ 422.4

Availability: 100 in stock
  • Condition: This device is in good cosmetic condition. It powers on and passes all self checks. Printer works to indicate this but it will not prime. There is a repair sticker from 2018 and this could possibly be the reason. Cartridges are online and easy to find. I am selling as-is.
  • Brand: Siemens DADE
  • All returns accepted: Returns Accepted
  • Intended Use/Discipline: Biological Laboratory
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • MPN: PFA 100
  • Item must be returned within: 30 Days
  • Model: Platelet Function Analyzer
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: United States

    Description

    Pinkmedical Sales ~ Deborah Godlevsky ~ Call or Text: 5207090315 Description This device is in good cosmetic condition with normal signs of wear from previous use. It passes all self tests and prints out a system check paper. It does all it needs to except prime. It has a 2018 Repair sticker and this could have possibly been the matter. In need of test cartidges which are easily available online in the following two tests: Collagen / Epinephrine and Collagen / ADP test cartridges. I am selling as-is because it navigates onscreen menus and the like but will not prime. This system is very easy to use with a few simple know how tips. When I first recieved the machine it wasn't working properly. The printer's paper roll was not on properly. I adjusted the roll to fit on the brackets, and it was fine. Then the carousel was stuck. The previous owner had put an extra cartridge holder in the carousel so it affected the spin. Easy fix. Next was the injection bottle in the dispenser. It needs to be in place and the handle competely in the down position. Then you are test ready! However, upon further testing it will not prime. I am unsure what the matter is. May need maintenance. The PFA-100 System has become the new standard for detection of platelet dysfunction. The PFA-100 Analyzer quickly and easily measures platelet plug formation in a small, whole blood sample (<1 mL) and reports a ”Closure Time” in 5-8 minutes. It is a unique system that challenges platelets under high shear flow conditions similar to the physiologic environment in which platelets normally function. It detects inherited-, acquired- or induced- platelet dysfunction by uniquely simulating, in vitro, the function of platelets in Primary Hemostasis.
    Siemens PFA 100 Platelet Function Analyzer DADE Behring Hematology LAB B4170-00
    Siemens PFA 100 Platelet Function Analyzer DADE Behring Hematology LAB B4170-00
    Click images to enlarge
    Description
    Pinkmedical Sales
    ~ Deborah Godlevsky ~ Call or Text:
    5207090315
    Description
    This device is in good cosmetic condition with normal signs of wear from previous use. It passes all self tests and prints out a system check paper. It does all it needs to except prime. It has a 2018 Repair sticker and this could have possibly been the matter. In need of test cartidges which are easily available online in the following two tests:
    Collagen / Epinephrine and Collagen / ADP test cartridges
    .
    I am selling as-is because it navigates onscreen menus and the like but will not prime.
    This system is very easy to use with a few simple know how tips. When I first recieved the machine it wasn't working properly. The printer's paper roll was not on properly. I adjusted the roll to fit on the brackets, and it was fine. Then the carousel was stuck. The previous owner had put an extra cartridge holder in the carousel so it affected the spin. Easy fix. Next was the injection bottle in the dispenser. It needs to be in place and the handle competely in the down position. Then you are test ready! However, upon further testing it will not prime. I am unsure what the matter is. May need maintenance.
    The PFA-100 System has become the new standard for detection of platelet dysfunction.
    The PFA-100 Analyzer quickly and easily measures platelet plug formation in a small, whole blood sample (<1 mL) and reports a ”Closure Time” in 5-8 minutes. It is a unique system that challenges platelets under high shear flow conditions similar to the physiologic environment in which platelets normally function. It detects inherited-, acquired- or induced- platelet dysfunction by uniquely simulating, in vitro, the function of platelets in Primary Hemostasis.
    Specifics
    Siemens PFA 100 Platelet Function Analyzer
    Serial - 01389
    100-240 V~ , 50/60 Hz , 1.5 Amps
    Principle - High Shear Force Dynamic Flow System
    Single Measuring Channel
    2 - Incubation Wells
    Incubation Temperature - 37.9C +-1.0C
    Sample - Citrated Whole Blood
    Sample Mechanism - Manual Pipette Dispensing 800µL
    Barcode Identification
    Single Test - Throughput 6 tests / hour
    Double Test - Throughput 10 tests / hour
    LCD Display
    Host Connection - Unidirectional / External PC RS-232 25 pin D Port
    Stored Control Results - Last 50 Results
    Stored Patient Results - Last 20 Results
    Software Update - PCMCIA Card
    Printer - Built in dot matrix printer, sound level printing 77dBA
    Manufacturer's Description
    The PFA-100
    ®
    System measures the complex process of primary hemostasis and aids in the rapid detection of platelet dysfunction. It is the first commercially available in vitro testing system to incorporate high-shear flow in which the process of platelet adhesion and aggregation following a vascular injury is simulated in-vitro.
    The PFA-100 System provides automated assessment for inherited, acquired, or drug-induced platelet dysfunction.
    Helps detect inherited, acquired and drug-induced platelet dysfunction
    Screening test for patients with impaired primary hemostasis, such as von Willebrand disease
    1
    Verifies efficacy of desmopressin acetate (DDAVP) therapy in pre-surgical patients
    2
    Assesses the platelet dysfunction due to the effect of Aspirin
    Evaluates platelet dysfunction in children over 1 year of age
    3
    Evaluates platelet dysfunction in multiple clinical settings, such as presurgical screening, high-risk pregnancy and menorrhagia
    Condition & Testing
    This device is in good cosmetic and excellent working condition with normal signs of wear from previous use. The front panel is a bit loose but does not affect the function of the device. Otherwise, The printer works and is perfect. The carousel spins and the machine is test ready. All buttons respond to prompts and easily navigates on-screen menus. Powers on and passes self-tests. Prints out a copy with the version of software, serial number, date and time (needs to be set), letting you know that the system is initializing. It runs a check on memory, vacuum chuck, carousel drive, and incubation system. Then a high and low flag of the two tests it is capable of performing. The LEDs are bright and legible and let you know that the system is test ready. No further testing has been done as it will not prime. Literature is available online.
    Age
    2018
    Dimensions
    Overall - 9" wide x 14" deep x 14" tall
    Power cord -
    Warranty
    I stand behind everything I sell and for 30 days I guarantee this
    Siemens PFA 100
    is exact to the description and pictures I have provided here or return it for a refund.
    Shipping
    Weight before packing is
    24.5 lbs
    for everything pictured.
    All buyers may use the shipping calculator.
    Pickup is always welcome from our warehouse in Coolidge Az 85128 (40 miles south of Phoenix Az near I-10).
    If the ebay shipping calculator wont give you a shipping cost you must contact me for a shipping quote.
    "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
    Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. There are no warranties which extend beyond the description on the face hereof. This item has been cleaned and handled in accordance with the manufacturer's instructions.
    .
    Godlevsky Enterprises LLC, Deborah Godlevsky,
    Coolidge Arizona,
    Used equipment sales,
    5207090315
    Pictures sell!
    Auctiva offers Free Image Hosting and Editing.
    300+
    Listing Templates!
    Auctiva gets you noticed!
    The complete eBay Selling Solution.
    Track Page Views With
    Auctiva's FREE Counter